Look, you don't know me from Adam. But I was a better man with you as a woman than I ever was with a woman as a man. Know what I mean?
Your position:Home->china company-> Holley MeteringLtd
Company Info
Holley Metering Limited is a cross-regional and export-oriented company focusing on the R&D, production, and marketing of energy meters. With 36 years experience in the metering field, Holley is now the biggest meter manufacturer in China. The domestic market share has been in No. 1 position over the last 12 years. The company provides wide range of products from mechanical residential meters to high precision C&I ones with reputable production capability and product quality.
Holley follows the strategy of internationalization actively and exports to more than 40 countries in the world. There are both IEC and ANSI conformed products, most of which are certified by internationally recognized laboratories. Local certification can also be obtained upon request.
With the goal to be one of the world's leading suppliers of energy meters and systems, Holley Metering Ltd. is looking forward to establishing mutual beneficial business relationships with partners from all over the world.
Member Info
Business Type: Manufacture
Annual Turnover: >100 Million US$
Number of Employees: > 1000
Business Scope: Electrical & Electronics, Metallurgy, Mineral & Energy
1. Single Phase Watt-hour Meter, Static Electronic Energy Meter
Product Description
Holley Metering Limited is a cross-regional and export-oriented company focusing on the R&D, production, and marketing of energy meters. With 36 years experience in the metering field, Holley is now the biggest meter manufacturer in China. The domestic market share has been in No. 1 position over the last 13 years. Holley follows the strategy of internationalization actively and exports to more than 40 countries in the world. There are both IEC and ANSI conformed products, most of which are certified by internationally recognized laboratories(KEMA).
DDS28 single-phase static watt-hour meter is designed for measuring active energy in single-phase alternating current power grids by connecting up resident power supply system. It complies with the standard IEC 61036 and has high measurement accuracy. The meter is KEMA certified and the design can be tailored to different customer requirements.
The meter is provided with pulse output, which makes remote control and locale consumption monitor possible. The DDS28 is a safe and optimized solution designed for the needs of deregulated energy market and automatic meter reading.
1. Technical data
Applicable Standard: IEC 61036-2000
Service Lifetime: 10 years
Accuracy Class: Class1, Class2
Working Voltage Range: 0. 7~1. 2Un
Power consumption Less than: 0. 7W or 6VA
Over voltage protection: 12kV
2. Basic functions
Energy display by register or LCD
Bi-directional active energy measurement
Operation indicated by pulse LED
S0 output with optical isolated output transistor corresponding to DIN 43864
3. Optional functions
Reverse indicator: An LED indicator will be on when the current is reversed
Anti-tamper in condition that load is connected between the line and the earth
Entirely closed register
HF magnet immune register
Reversal preventing register
Transformer connection
4. Specification
Rated Voltage: 110 V, 120V, 220V, 230V, 240V
Reference frequency: 50Hz or 60Hz
Basic Current (Maximum Current)
2. 5(10) 5(20) 10(40) 20(80)
2. 5(15) 5(30) 10(60) 20(100)
HS Code: 90283010
Trademark: Holley
Model: DDS28
Standard: IEC 61036
Productivity: 3000Pcs / Day
Origin: Chinese
Packing: cartons
Min. Order: 500pcs
Transportation: by sea, by train, by air
2. HLD06 Single Phase Mechanical Meter
Product Description
1. General
The Hld06 Single-Phase Meter Is A Socket Type Meter Designed To Meet The Latest Ansi C 12. 1 And Ansi C 12. 10 Standards. The Meter Measures Active Energy In Single-Phase Two Wire Or Three Wire Alternating Current Power Grids. Connection Is Fm 1s And Fm 2s. It Is A Reliable Long Service Life Meter. The Average Service Life (Mttf) Is 30 Years And The Maximum Current Is 200a. Both Cyclometer-Type And Pointer Registers Are Available. In Addition, It Can Be Equipped With An Amr Module.
2. Construction
2. 1 Meter Case
The Socket Type Meter Case Complies With Ansi C 12. 7-1993 And Meets The Protection Requirements Set By Ansi C 12. 10-1993.
2. 2 Driving Element
The Driving Element Consists Of A Voltage Element And A Current Element, Both Of Which Are Fixed On The Aluminum Alloy Frame. It Has A Load Curve Compensation Mechanism And An Inductive Load Adjustment Mechanism.
2. 3 Rotor
The Worm Is An Un-Detachable Part Of The Shaft So That The Mesh Between The Worm And Shaft Is Improved. Both Ends Of The Shaft Are Embedded With Graphite Bearing To Ensure The Long Service Life Of The Meter.
2. 4 Upper Bearing
The Upper Bearing Consists Of A Guide Pin And An Aluminum Sleeve.
2. 5 Lower Bearing
The Lower Bearing Consists Of A Guide Pin And A Brass Sleeve, And Is Fixed Into The Meter Frame By One Screw.
2. 6 Braking Element
Two Magnet Cubes Are Die-Casted Into The Meter Frame By Aluminum Alloy. It Has A Temperature Compensation Plate.
2. 7 Frame
The Frame Is Die-Casted By High Quality Sial Alloy Of Stable Property To Avoid Distortion. It Has A Low Load Adjustment Mechanism.
2. 8 Register
Both Pointer And Cyclometer Registers Are Available.
3. Technical Data
Meter Type: Hld06
Applicable Standards: Ansi C12. 1 And Ansi C12. 10
Class: 10\20\100\200
Test Current Ib: (A) 2. 5\2. 5\15\30
Meter Constant: (R/Kwh)1400\1200\360\90
Average Service Life (Mttf): 30 Years
Overload Capacity %Ib 667
Heat Capacity: Ib+Imax
Short Time Over Current: 7000a Short Circuit 0. 1s
Reference Voltage Un V 110v, 120v, 220v, 230v, 240v, 277v, And 480v
Reference Frequency: 60hz
Non-Running With No-Load: 0. 9~1. 1un
Starting Current 1%Ib
Rated Load Speed At Ib: 11 R/Min
Power Losses In Voltage Circuit At 60hz Un <1w/5va
Power Losses In Current Circuit At Ib <0. 5va
A. C. Voltage Test At 60hz, 1min, 2. 5kv
Impulse Voltage Test 1. 2/50ms >6. 5kv
Rated Load Torque At Unity Pf, Ib 400u N. M
Weight Of Rotor: 26 G
Weight Of Meter: Approximately 1. 7kg
Main Case Bakelite Base/Glass Cover
Register Pointer Or Cyclometer Type
Option Reverse Running Stopper, Pulse Sampling Device
HS Code: 90283010
Trademark: Holley
Model: HLD06
Standard: ANSI
3. Single Phase Electronic Electricity Meter(DDS28u)
Product Description
1 Introduction
DDS28u single-phase multi-function PLC electronic watt-hour meter is designed for balancing electricity better as well as measuring household electric energy with time-sharing technology. It can measure active energy, communicate via remote infrared or PLC, freeze energy automatically in auto-read-day monthly and in auto-read-time daily, and so on.
Measuring the active energy accurately, the meter can be used as the terminal of the AMR system. It can communicate with concentrator, which is installed in the distribution substation, via PLC. It can send the data, for example energy information, to concentrator in semi-duplex mode. So it is an ideal option for measuring resident electric energy consumption, AMR system and measuring with time-sharing technology.
DDS28u complies with the standard IEC61036 "Alternating current static watt-hour meters for active energy (class1 and 2)".
2 Specifications
Meter type Specifications Accuracy class Meter constant(imp/kWh)
DDS28u 220V 10(60) A Active 1 1600
3 Technical indexes
3.1 Normal working voltage: 0.8Un~1.1Un
3.2 Limit of working voltage: 0.7Un~1.2Un
3.3 Normal working temperature range: -25C~+55C
3.4 Limit of working temperature: -40C~+70C
3.5 Humidity: 25%RH~85%RH
3.6 Power consumption: ≤2W(active); ≤2.5VA(apparent)
3.7 Clock accuracy:Daily timing error less than 0.5S(23+-2C)
3.7 Max distance of infrared communication: >4m
3.8 Distance of PLC communication:3 km. of main Power Line.
3.9 Dimension of profile: 164.5*112*71mm(fig.1)
3.10 Net Weight: 0.9 kg
4 Function
4.1 Meter can measure active energy and reactive energy. And reactive energy will be plus to active energy automatically.
4.2 Multi-tariff function
4.2.1 One day can be divided maximally into 10 time periods. Each time period can choose one tariff from four. The maximal time error changing from one tariff to other is 1 second.
4.2.2 One year can be divided maximally into 4 seasons. Each season can choose one period-tariff table from four. The season can be set. The meter can change relative parameters automatically when the season is turning.
4.3 Energy frozen automatically
User can set the date and time of the user-read-day. Meter can freeze the total energy and the energy of every tariff at user-read-day of every month automatically. When it run in to a new user-read-day, the new freezing data will replace the old one in the storage of the meter. It can store six days of freezing daily data and eleven month of freezing monthly data at most.
4.4 History energy Record
Meter can store history energy data of 12 months, energy data of every tariff and the total number of days when meter has no load. All data can be accessed via infrared or PLC.
4.5 Event Log
It can record last five times of power down, including the total happening time of each event plus their respective latest five starting time and ending time.
4.6 Alarm
Meter has LCD alarm function, and it can alarm when voltage of the clock battery is too low or user operates falsely. When some part of the meter, for example the relay, works abnormally or the load of the meter is too large, meter also can alarm. All alarm information can be accessed via HHU or PLC.
4.7 Inspecting function
4.8 Data preservation function
4.9 Anti-temper function
4.10 Inspect failure of relay When the relay works abnormally, meter can alarm.
4.11 Compelling control function (remotely control)
On the basis of the data real time read form meter, user can control transmitting electricity by switching the relay. User can switch the relay by HHU, when it is unsuccessful to control the relay remotely by energy managing system.
4.12 Real time power control function (automatically control)
4.13 Infrared communication
4.14 Broadcast Rectify
4.15 Input and output interface
HS Code: 90283010
Trademark: Holley
Model: DDS28u
Standard: IEC61036
Unit Price/Payment: FOB USD36.00/pc
Origin: Hangzhou
Packing: Carton
Min. Order: 500pcs
Transportation: By, sea, air
4. Static Single Phase Meter(DDS1088)
Product Description
Specification:
Voltage: 120V, 240V
Current: 10(60) A, 15(100) A
Connection: direct connection
Start current: 0.4%Ib
Power consumption: < 1W, 6VA
Working Voltage: 0.7Un ~1.2 Un
Working Temperature: 10C~60C
Humidity: <80%
Functions:
Adopt Large Scale Integrated circuit, SMT technology
Bi-directional active energy measurement
Pulse output
Anti-tamper function
LCD or Register Display
Protective class II
Cover and base Material is Bakelite, PC, ABS, so it has non-flammability.
Optional function: Optical communication and RS485 communication
HS Code: 90283010
Trademark: Holley
Model: DDS1088
Standard: ANSI12.1
Packing: 4Pcs/Carton
Min. Order: 400Pcs
Transportation: by sea, by air
5. Three Phase Electro-Mechanical Watt-hour Meter (DT58)
Product Description
General
The DT58 three-phase four-wire meter is designed to meet the latest IEC60521 and BS EN 60521 standards for measuring active energy in three-phase four-wire alternating current power grids. Connection is direct or by instrument transformers. The meter is KEMA certified. It has an average service life (MTTF) of 20 years and maximum overload capacity of 600%Ib.
1.Meter case
It meets the protection requirements set by protection class IP53 of IEC60529. The series types of cases and terminal covers are available.
2.Terminals & Terminal block
Terminals:
The connection terminals are made of nickel-plated brass with features of high mechanical strength, good conductivity and corrosion-resistance.
Terminal block:
The terminal block is injection molded of heat- and fire-resistant Bakelite. The voltage test link can be located inside or outside of the meter case.
3.Driving system
The driving system employs three single electromagnet elements, all of which are mounted on the meter frame with three screws. Each electromagnet element consists of voltage element, current element and connection board.
4.Rotor
The rotor shaft is turned of high strength aluminum alloy. The upper end of the shaft is pressed with a worm which is made of thermoplastic, and the lower end is embedded with a graphite bearing which is self-lubricate and friction-resistant to ensure long service life of the meter.
5.Braking element
The magnet is made of AlNiCo5 alloy and designed as U-shaped so that the effect of short time over currents upon the magnet is negligible. A temperature compensation plate, made of a special alloy, is embedded in the braking magnet. The rotor speed can be adjusted largely and continuously by rotating the whole magnet.
6.Frame
The frame is die-casted by high quality SiAl alloy. Its structure is designed as W-shaped of stable property to avoid distortion, and its surface is treated with chromate to achieve reliable and durable coating against oxidation.
7.Upper bearing
The pin is made of abrasion-proof stainless steel, and pressed into the brass sleeve. It is the rotor guide and runs in the plastic worm of the rotor.
8.Lower bearing
The magnetic suspension bearing consists of two ring shaped magnets, a guide pin and a bearing base. The pin made of stainless steel runs in the graphite sleeve of the rotor. No lubrication is needed.
9.Register
The cyclometer type register consists of six drums. It can be read directly. The drum is made of polycarbonate. The framework is embedded with a high-strength self-lubricating plastic bearing. No lubrication of bearings is needed during the service life.
10. Technical data
1 Meter type:DT58
2 Standards:IEC60521.IEC514
3 Accuracy(according to IEC60521)
Transformer operated: Class 1
Direct connected: Class 2
4 Average service life (MTTF): 20 years
5(6) Basic current (Maximum current)A: 1.5(6) 3(6) 5(20) 5(40) 10(60) 15(60) 20(80)
7 Rating current of transformer in 5A direct connection
8 Reference voltage Un 3X57.7/100V, 3X220/380V, 3X230/400V, 3X240/415V
9 Reference frequency: 50 Hz.60 Hz
10 Power losses in voltage circuit at 50 Hz Un: 1.0 W/4.5 VA
11 Power losses incurrent circuit at 50Hz Un Ib <0.5 VA
12 Non-running with no-load: 0.8~1.1Un
13 Starting current: 0.4%Ib 0.5%Ib
14 Mean temperature coefficient: From 0.1Ib to Imax at unity PF From 0.2Ib to Imax at unity 0.5 lagging <0.08%/0C<0.12%/0C
15 Insulation level: Withstand A.C. Voltage for 50 Hz, 1min Withstand impulse voltage 1.2/50us >2 kV (when bakelite base>4kV) >6kV (when bakelite base>8kV)
16 Rated load torque at unity PF, Ib >800uNm
17 Weight of rotor 48 g
18 Weight of meter =3.5kg
19 Meter base: Steel, Bakelite, and PC
20 Meter cover: Bakelite, transparent PC
21 Terminal cover: ABS, Bakelite, PC
22 Register: Cyclometer single, Unidirectional, Jumping
23 Option Reverse running stopper
HS Code: 90283010
Trademark: Holley
Model: DT58
Standard: IEC 60521
Contact Details
Company Name: Holley Metering Ltd.
Company Address: No. 18, Xidoumen Road, Hangzhou, Zhejiang, China
City/Province: Hangzhou/Zhejiang
Country/Region: China
Zip/Postal Code: 310012
Telephone Number: 86-571-88471722
Fax Number: 86-571-88471723
Contact Person: Raymond Zheng
Position: Regional Sales Manager
Department: Overseas Business Department